Yaskawa Sigma II Series Servo System User Manual

Page 364

Advertising
background image

Sigma II User’s Manual

Chapter 8: Ratings and Characteristics

8 - 34

Specifications for Servo Amplifier and Three-phase, 400V

Servomotor Combinations

*1

Allowable regenerative frequency is the number of times the servomotor is allowed to accelerate and

decelerate through a 0rpm

→ maximum motor speed → 0rpm cycle in a minute.

Voltage

Three-phase 400V

Servo Amplifier Model

SGDH-

05DE

10DE

15DE

20DE

30DE

50DE

60DE

75DE

1ADE

1EDE

SG

MG

H

S

er

ies

Appl

ica

ble

Se

rv

om

ot

or

Model

SGMGH-

05D

09D

13D

20D

30D

44D

55D

75D

1AD

1ED

Capacity

(kW)

0.45

0.85

1.3

1.8

2.9

4.4

5.5

7.5

11

15

Motor Speed

(rpm)

Rated 1500/maximum 3000

Rated 1500/

maximum 2000

Applicable Encoder

Standard: 17-bit incremental encoder

Continuous Output

Current

A

rms

1.9

3.5

5.4

8.4

11.9

16.5

20.8

25.4

28.1

37.2

Maximum Output Current

A

rms

5.5

8.5

14

20

28

40.5

55

65

70

85

Allowable Regenerative

Frequency

*1

(times/min)

42

15

10

12

8

11

26

18

36

32

SGMSH Series

Appl

ica

ble

Se

rv

om

ot

or

Model

SGMSH-

10D

15D

20D

30D

40D

50D

Capacity

(kW)

1.0

1.5

2.0

3.0

4.0

5.0

Motor Speed

(rpm)

Rated 3000/maximum 5000

Applicable Encoder

Standard: 17-bit incremental encoder

Continuous Output

Current

A

rms

2.8

4.7

6.2

8.9

12.5

13.8

Maximum Output Current

A

rms

8.5

14

19.5

28

38

42

Allowable Regenerative

Frequency

*

(times/min)

47

31

48

20

29

22

Advertising