MCCB or Fuse According to Power Capacity

The following table shows the MCCB or fuse capacity for each power supply

capacity.

*1

This is the net value at the rated load. When actually selecting fuses, determine the capacity with enough
margin for peak power operation.

*2

Operating characteristics (at 25°C): 2 seconds or more for 200%, 0.01 second or more for 700%

Notes: 1. A fast-operating fuse cannot be used because the servo amplifier power supply is a capacitor

input type. A fast-operating fuse may blow when the power is turned ON.

2. SGDH servo amplifiers do not have built-in ground protection circuits. To configure a safer

system, install a ground fault interrupter with or without a circuit breaker for protection against
overload and short circuit conditions.

Main Circuit

Power

Supply

Servo Amplifier

Model

Applicable Motor

Power Capacity per

Servo Amplifier

(kVA)

*1

Current Capacity per

MCCB or Fuse

(A

rms

)

*1, *2

Capacity

(kW)

SGDH-

Single-phase,

100V

0.03

A3BE

SGMAH-A3B

0.15

4

0.05

A5BE

SGMAH-A5B

0.25

0.10

01BE

SGMAH-01B

0.40

SGMPH-01B

0.20

02BE

SGMAH-02B

0.60

6

SGMPH-02B

Single-phase,

200V

0.03

A3AE

SGMAH-A3A

0.20

4

0.05

A5AE

SGMAH-A5A

0.25

0.10

01AE

SGMAH-01A

0.40

SGMPH-01A

0.20

02AE

SGMAH-02A

0.75

SGMPH-02A

0.40

04AE

SGMAH-04A

1.2

8

SGMPH-04A

0.75

08AE-S

SGMAH-08A

2.1

11

SGMPH-08A

1.50

15AE-S

SGMPH-15A

4.0

19

Advertising