background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 43

The maximum speed of the servomotor will be used if Pn407 is set to a value higher
than the maximum speed of the servomotor.

External Speed Limit function:

This function sets the voltage range for speed reference input V-REF (CN1-5)
according to the output range of the host controller or external circuit.
When the default setting (600) is multiplied by 0.01V, the result (6V) corresponds to
the rated motor speed.

The default setting is 6V = the rated motor speed.

Principle of Speed Limit

When the control speed range is exceeded, torque, inversely proportional to the

difference between the speed limit and the actual speed, is fed back in order to return
the system to a level within the control speed range. In effect, the actual motor speed
limit depends on the load condition.

Parameter

Signal

Setting

(0.01V

/Rated Speed)

Control Mode

Pn300

Speed Reference Input Gain

Setting Range: 150 to 3000

Default Setting: 600

Speed/Torque Control

Reference voltage (V)

Reference

speed

(rpm)

This slope is set.

Speed

limit

range

Motor speed

V-REF