Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 26

5.2.4

Sequence I/O Signals

Sequence I/O signals are used to control servo amplifier operation. Connect these
signal terminals as required.

Input Signal Connections

Connect the sequence input signals as shown below.

Note: Provide a separate external I/O power supply; the servo amplifier does not have an internal 24V

power supply.

External power supply specifications: 24V ±1 V

DC

, 50mA minimum.

Yaskawa recommends using the same type of external power supply as that used for output circuits.

The function allocation for sequence input signal circuits can be changed.
See 5.3.3 Input Circuit Signal Allocation for more details.

The external power supply input terminal is common to sequence input signals.

Contact input signals:

/S-ON (CN1-40)
/P-CON (CN1-41)
P-OT (CN1-42)
N-OT (CN1-43)
/ALM-RST (CN1-44)
/P-CL (CN1-45)
/N-CL (CN1-46)

Input +24VIN CN1-47

External I/O Power Supply Input

Speed/Torque Control,

Position Control

I/O power

supply

CN1-47

CN1-40

CN1-41

CN1-42

CN1-43

CN1-44

CN1-45

CN1-46

0V

+ 24V

Servo Amplifier

Photocoupler

Host controller

+24V

IN

/S-ON

/P-CON

P-OT

N-OT

/ALM-RST

/P-CL

/N-CL

3.3k

Ω

Servo amplifier

I/O power supply

Connect an external I/O power supply

+24V

+24V

in

CN1-47