Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 7

Position Control Mode

The following tables list and explain the meanings of bit data and code displays in
Position Control Mode.

Bit Data and Meanings in Position Control Mode

Bit Datum

Meaning

Control Power ON

Lit when servo amplifier control power is ON.

Baseblock

Lit for baseblock.

Not lit when servo is ON.

Positioning Completed

Lit if error between position reference and actual motor position

is below preset value.

Preset value: Set in PN500. (Default setting is 7 pulses).

/TGON

Lit if motor speed exceeds preset value.

Preset value: Set in Pn502. (Default setting is 20rpm).

Reference Pulse Input

Lit if reference pulse is input.

Error Counter Clear Input

Lit when error counter clear signal is input.

Power Ready

Lit when main power supply circuit is operating at normal level.

Not lit when power is OFF.

Codes and Meanings in Position Control Mode

Code

Meaning

Baseblock

Servo OFF (motor power OFF)

Run

Servo ON (motor power ON)

Forward Run Prohibited

CN1-42 (P-OT) is OFF. Refer to 5.1.2 Setting the Overtravel Limit

Function.
Reverse Run Prohibited

CN1-43 (N-OT) is OFF. Refer to 5.1.2 Setting the Overtravel Limit

Function.

Alarm Status

Displays the alarm number. Refer to 9.2 Troubleshooting.

Code

Bit Data

Positioning Completed

Baseblock

Control Power ON

Reference Pulse Input

TGON
Power Ready

Error Counter Clear Input