Chapter 7: Using the Digital Operator

7 - 6

Speed and Torque Control Mode

The following tables list and explain the meanings of bit data and code displays in
Speed, and Torque Control Modes.

Bit Data and Meanings in Speed and Torque Control Mode

Bit Datum

Meaning

Control Power ON

Lit when servo amplifier control power is ON.

Baseblock

Lit for baseblock.

Not lit when servo is ON.

Speed Coincidence

Lit when the difference between the motor speed and reference

speed is the same as or less than the value set in Pn503.

(The default value set in Pn503 is 10rpm).

/TGON

Lit if motor speed exceeds preset value

Preset value: Set in Pn502. (Default setting is 20rpm).

Speed Reference Input

Lit if input speed reference exceeds preset value.

Specified value: Set in Pn502. (Default setting is 20rpm)

Torque Reference Input

Lit if input torque reference exceeds preset value.

Preset value: 10% rated torque is default setting

Power Ready

Lit when main power supply circuit is operating at normal level.

Not lit when power is OFF.

Codes and Meanings in Speed and Torque Control Mode

Code

Meaning

Baseblock

Servo OFF (motor power OFF)

Run

Servo ON (motor power ON)

Forward Run Prohibited

CN1-42 (P-OT) is OFF. Refer to 5.1.2 Setting the Overtravel Limit

Function.
Reverse Run Prohibited

CN1-43 (N-OT) is OFF. Refer to 5.1.2 Setting the Overtravel Limit

Function.

Alarm Status

Displays the alarm number. Refer to 9.2 Troubleshooting.

Bit Data

Code

Speed Coincidence*

Speed Reference input

BaseBlock

Control Power ON

TGON

Torque Reference Input

Power Ready

* This indicator is always lit when the Servopack is in torque control mode.