3 resetting servo alarms, 3 resetting servo alarms - 4, Resetting servo alarms -4 – Yaskawa Sigma II Series Servo System User Manual

Page 278: Important, Using the hand-held digital operator, Using the built-in panel operator

Advertising
background image

Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 4

7.1.3

Resetting Servo Alarms

Servo alarms can be reset using the digital operator.

Using the Hand-held Digital Operator

Press the RESET key in status display mode.

Using the Built-in Panel Operator

Press the Up Arrow AND Down Arrow keys together in status display mode.
The alarm can be reset with CN1-44, or /ALM-RST signal input. Refer to 5.5.1
Using Servo Alarm and Alarm Code Outputs.
The servo alarm will be reset if the control power supply is turned OFF.

• If an alarm is ON, reset the alarm after eliminating the cause of the alarm first. Refer to 9.2 Troubleshooting.

SGDM-

MODE/SET DATA/

SERVOPACK

200V

YASKAWA

Built-in Panel Operator

Key

Name

Function

Up Arrow

Key

• Press this key to set parame-

ters or display the set values of

parameters.

• Press the Up Arrow key to

increase the set value.

• Press the Down Arrow key to

decrease the set value.

• Press the Up and Down Arrow

keys together to reset a servo

alarm.

Down Arrow

Key

MODE/SET

Key

Press this key to select the status

indicator mode, auxiliary function

mode, parameter setting mode, or

monitor mode.

DATA/SHIFT

Key

• Press this key to set each

parameter or display the set

value of each parameter.

• This key is used for selecting

the editing (flashing) digit or

data setting.

MODE/SET

DATA/

IMPORTANT

Advertising