Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 17

Output Signal Monitor Display

4 3 2 1 Number

7 6 5

Top: ON = High level
Bottom: ON = Low level

Note: Refer to 5.3.4 Output Circuit Signal Allocation for details on output terminals.

Output signals are allocated as shown above and displayed on the panel of the servo
amplifier or the digital operator. They are indicated by the ON/OFF status of the
vertical parts of seven-segment displays located in top and bottom rows. (The

horizontal segments are not used here). These turn ON or OFF relative to the state
of the corresponding output signals (ON for “L” level and OFF for “H” level).

Example

When ALM signal operates (alarm at “H”)

LED Number

Output Terminal Name

Default Setting

1

(CN1-31, -32)

ALM

2

SO1 (CN1-25, -26)

/COIN or /V-CMP

3

SO2 (CN1-27, -28)

/TGON

4

SO3 (CN1-29, -30)

/S-RDY

5

(CN1-37)

AL01

6

(CN1-38)

AL02

7

(CN1-39)

AL03

4 3 2 1 Number

7 6 5

Only the top segment

of number 1 is lit.