Using the built-in panel operator – Yaskawa Sigma II Series Servo System User Manual

Page 324

Advertising
background image

Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 50

4.

Press the DSPL/SET key. The display will change as shown below and offset
will be automatically adjusted.

5.

Press the DATA/ENTER key to return to the auxiliary function mode display.

This completes the automatic adjustment of the motor current detection offset.

Using the Built-in Panel Operator

1.

Press the MODE/SET key to select the auxiliary function mode.

2.

Press the Up Arrow or Down Arrow key to select the parameter Fn00E.

3.

Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below.

4.

Press the MODE/SET key. The display will change as shown below and the
offset will be automatically adjusted.

5.

Press the DATA/SHIFT key for a minimum of one second to return to the

auxiliary function mode display.

This completes the automatic adjustment of the motor current detection offset.

Flashing

for one

second

SGDM-

MODE/SET

DATA/

CHARGE

POWER

SERVOPACK

200V

YASKAWA

Flashing

for one

second

Advertising