Sigma II User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9 - 35

CPF00

CPF00: Digital Operator Transmission Error 1

This alarm is not stored in the alarm history.
The watch dog timer time dout due to an excessively long command associ-
ated with the application module (e.g. JUSP NS300). In such cases the
amplifier will recover automatically.

Display and Outputs

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Output

ALM Output

ALO1

ALO2

ALO3

Not Applicable

Cause of the Problem

Solution

A

Cable defective or poor contact

between digital operator and

servo amplifier.

• Check connector connections.

• Replace cable.

B

Malfunction due to external noise.

Separate digital operator and

cable from noise source.

C

Digital operator defective.

Replace digital operator.

D

Servo amplifier defective.

Replace servo amplifier.

When the digital operator

is connected before or after

the servo amplifier has been

turned ON.

A, B

C, D