A.40: Main Circuit DC Voltage Error Detected: Overvoltage

Display and Outputs

Note:

OFF:

Output transistor is OFF (alarm state).

ON:

Output transistor is ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Output

ALM Output

ALO1

ALO2

ALO3

OFF

OFF

ON

OFF

Cause of the Problem

Solution

A

Power supply voltage is not within

the range of specifications.

Check power supply.

B

Load exceeds capacity of the regen-

erative unit.

Check specifications of load iner-

tia and overhanging load.

C

Malfunctioning regenerative transis-

tor.

Replace servo amplifier.

D

Defective rectifying diode.

E

Defective servo amplifier.

A, B, C, D

E

A, D

During servomotor
operation.

When main circuit
power is turned ON.

When control power
is turned ON.