Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 13

7.

Press the DATA/ENTER key once more to return to the parameter number

display.

This has changed the 1 digit of parameter Pn000 to “1”.

Using the Built-in Panel Operator

1.

Press the MODE/SET key to select the parameter setting mode.

2.

Press the Up Arrow or Down Arrow key to select the parameter number to
be set. (Pn000 is selected in this example.)

3.

Press the DATA/SHIFT key for a minimum of one second to display the current
data for the selected parameter.

4.

Press the DATA/SHIFT key to select the digit to be set.

5.

Press the Up Arrow or Down Arrow key to select the value defined as a
function setting for the selected digit.

Repeat the above steps 4 and 5 for changing the data as required.

6.

Press the DATA/SHIFT key for a minimum of one second to save the data. The
display will flash.

SGDM-

MODE/SET

DATA/

CHARGE

POWER

SERVOPACK

200V

YASKAWA

Digit to be set

Digit to be set

Digit to be set

Advertising