2 three-phase (200v) main circuit specifications, Three-phase (200v) main circuit specifications -5, Sigma ii user’s manual chapter 3: wiring 3 - 5 – Yaskawa Sigma II Series Servo System User Manual

Page 43

Advertising
background image

Sigma II User’s Manual

Chapter 3: Wiring

3 - 5

3.1.2

Three-Phase (200V) Main Circuit Specifications

Host
Controller

Connect the SGDH servo amplifier
to a Yaskawa host controller or to
one made by another company.

MEMOCON GL120, GL130

with a motion module.

Molded-Case Circuit

Breaker (MCCB)

Noise Filter

Magnetic Contactor

Brake Power Supply

Regenerative Resistor

Digital Operator

Personal Computer

Encoder

Cable

Encoder

Connector

JUSP-OPO2A-1

Allows the user to

set parameters or

operation references

and to display opera-

tion or alarm status.

Communication

and control is also

possible with a

personal computer.

Cable model: YS-12

Used to eliminate external

Protects the power

Used for a servomotor

Connect an external regenerative

line by shutting

OFF the circuit

when overcurrent

is detected.

HI Series

noise from the power line.

Turns the servo

ON and OFF.

Install a surge

suppressor on

the magnetic

contactor.

with a brake.

resistor to terminals B1 and B2 if

the regenerative capacity is

insufficient.

and JZSP-CMS00-1

(cable)

Brake
power
supply

Magnetic

Magnetic
contactor

contactor

Power
supply
ground
line

Noise filter

Power supply
Three-phase 200V

AC

R S T

MCCB

Regenerative

resistor

(optional)

For 6kW or higher, an external

resistor is required.

Advertising