Operating example, Acceleration used as detection point – Yaskawa Sigma II Series Servo System User Manual

Page 249

Advertising
background image

Sigma II User’s Manual

Chapter 6: Servo Adjustment

6 - 17

Operating Example

In this example, the mode switch is used to reduce setting time. Generally, speed
loop gain must be increased to reduce setting time. Using the mode switch
suppresses the occurrence of overshoot and undershoot as speed loop gain is
increased.

Acceleration Used as Detection Point

If motor acceleration exceeds the value set in parameter Pn10E, the speed loop
switches to P control.

Motor speed

Speed reference

Without mode switch

Long setting time

Increase speed loop gain.

Overshoot

Without mode switch

With mode switch

Setting time

Suppress overshooting

and undershooting.

Motor

speed

Motor

speed

Motor

speed

Undershoot

Time

Motor speed

Reference speed

Speed

Motor acceleration

+Pn10E

Acceleration 0

-Pn10E

PI control

PI control

PI control

P control

P control

Advertising