Yaskawa Sigma II Series Servo System User Manual

Page 199

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-113

*1

This is the net value at the rated load. When actually selecting fuses, determine the capacity using the pre-
scribed derating.

*2

Operating characteristics (at 25°C): 2 seconds or more for 200%, 0.01 second or more for 700%

Notes: 1. A fast-operating fuse cannot be used because the servo amplifier power supply is a capacitor

input type. A fast-operating fuse may blow when the power is turned ON.

2. SGDH servo amplifiers do not have built-in ground protection circuits. To configure a safer

system, install a ground fault interrupter with or without a circuit breaker for protection against
overload and short circuit conditions.

Main Circuit

Power

Supply

Servo Amplifier

Model

Applicable Motor

Power Capacity per

Servo Amplifier

(kVA)

*1

Current Capacity per

MCCB or Fuse

(A

rms

)

*1, *2

Capacity

(kW)

SGDH-

Three-phase,

200V

0.45

05AE

SGMGH-05A A

1.4

4

SGMGH-03A B

0.75

08AE

SGMAH-08A

1.9

7

SGMPH-08A
SGMGH-06A B

1.0

10AE

SGMGH-09A A

2.3

SGMGH-09A B
SGMSH-10A

1.5

15AE

SGMPH-15A

3.2

10

SGMGH-13A A
SGMGH-12A B
SGMSH-15A

2.0

20AE

SGMGH-20A A

4.3

13

SGMGH-20A B
SGMSH-20A

3.0

30AE

SGMGH-30A A

5.9

17

SGMGH-30A B
SGMSH-30A

5.0

50AE

SGMSH-40A

7.5

28

SGMGH-44A A
SGMSH-50A

6.0

60AE

SGMGH-55A A

12.5

32

7.5

75AE

SGMGH-75A A

15.5

41

11

1AAE

SGMGH-1AA

22.7

60

15

1EAE

SGMGH-1EAE

30.9

81

Advertising