Sigma II User’s Manual

Chapter 2: Installation

2 - 7

2.2 Servo Amplifiers

The SGDH servo amplifiers are base-mounted servoamps. Incorrect installation will
cause problems. Follow the installation instructions below.

2.2.1

Storage Conditions

Store the servo amplifier within the following temperature range, as long as it is
stored with the power cable disconnected.
-20 to 85°C

2.2.2

Installation Site

The following precautions apply to the installation site.

Situation

Installation Precaution

Installation in a Control

Panel

Design the control panel size, unit layout, and cooling

method so the temperature around the servo amplifier

does not exceed 55°C.

Installation Near a

Heating Unit

Minimize heat radiated from the heating unit as well as

any temperature rise caused by natural convection so

the temperature around the servo amplifier does not

exceed 55°C.

Installation Near a

Source of Vibration

Install a vibration isolator beneath the servo amplifier to

avoid subjecting it to vibration.

Installation at a Site

Exposed to Corrosive

Gas

Corrosive gas does not have an immediate effect on the

servo amplifier, but will eventually cause electronic

components and contactor-related devices to malfunc-

tion. Take appropriate action to avoid corrosive gas.

Other Situations

Do not install the servo amplifier in hot and humid

locations or locations subject to excessive dust or iron

powder in the air.