Yaskawa Sigma II Series Servo System User Manual

Page 164

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-78

The following parameter setting is used to change the CN1 connector terminal that
outputs the /TGON signal.

The parameter is default set so the /TGON signal is output between CN1-27 and 28.
See 5.3.4 Output Circuit Signal Allocation for more details on parameter Pn50E.
This parameter is used to set output conditions for the operation detection output

signal /TGON.

This parameter is used to set the speed at which the servo amplifier determines that
the servomotor is running and then to output an appropriate signal. The following
signals are generated when motor speed exceeds the preset level.
Signals generated when servomotor operation is detected:

/TGON

Status Indication Mode

Monitor Mode Un006

Parameter

Signal

Setting

(rpm)

Description

Pn50E

Output Signal Selections 1

Default Setting: 3211

Position Control

Parameter

Signal

Setting

(rpm)

Description

Pn502

Rotation Detection Level

Setting Range: 1 to 10000

Default Setting: 20

Speed/Torque Control,

Position Control

Motor speed

(Un000)

/TGON

Pn502