Using the built-in panel operator – Yaskawa Sigma II Series Servo System User Manual
Page 322

Sigma II User’s Manual
Chapter 7: Using the Digital Operator
7 - 48
Using the Built-in Panel Operator
1.
Press the MODE/SET key to select the auxiliary function mode.
2.
Press the Left Arrow or Right Arrow key to select the parameter Fn00D.
3.
Press the DATA/SHIFT key for a minimum of one second, and the display will
be as shown below.
4.
Press the MODE/SET key. Each time the MODE/SET key is pressed, the
monitor output will toggle between the displays for the two channels shown
below.
5.
Press the DATA/SHIFT key for less than one second. The gain parameter for the
analog monitor will be displayed. Pressing the DATA/SHIFT key again for less
than one second will return to the display shown above in step 3 or 4.
6.
Press the Up Arrow or Down Arrow key to adjust the gain for the analog
monitor output.
7.
When the gain adjustment has been completed for the two channels, press the
DATA/SHIFT
key for a minimum of one second to return to the auxiliary
function mode display.
This completes the manual gain adjustment of the analog monitor output.
SGDM-
MODE/SET
DATA/
CHARGE
POWER
SERVOPACK
200V
YASKAWA
MODE/SET Key
Displayed
Alternately
Data Display
DATA/SHIFT Key
Displayed
Alternately
Data Setting Change