Appendix B: List of Parameters
B - 6
Position Rel
ated
Parameters
Pn207
Position Control
Function Switches
*1
–
0000H
1111H
0000H
The setting
on 2nd digit
is added.
Pn212
PG Dividing Ratio
*1 and 3
pulse
0000000016
107374182
4
2048
Newly
added
Pn217
Reference Pulse
Input
Multiplication
×
1
1
99
1
Newly
added
Pn218
Reference Pulse
Multiplication
Function Selection
*1
–
0000H
0001H
0000H
Newly
added
Pn281
PG Dividing Ratio
(Only for linear
motors)
*1
pulse/
scale pitch
1
255
20
Upper limit
is modified
from 256 to
255.
Spe
ed
Rela
te
d
Parameters
Pn309
Reserved (Do not
change.)
rpm
0
500
60
Newly
added
Pn384
Motor Max. Speed
(Only for linear
motors)
100mm/s
1
100
50
Newly
added
Torq
ue
Rel
ate
d
Parameters
Pn408
Torque-related
Function Switches
Å|
0000H
0101H
0000H
The setting
on 2nd digit
is added.
Pn40A
Notch Filter Q
Value
×
0.01
50
400
70
Newly
added
Pn40B
Second Stage
Notch Filter
Frequency
Hz
50
2000
2000
Newly
added
Pn40C
Second Stage
Notch Filter Q
Value
×
0.01
50
400
70
Newly
added
Cat.
Paramete
r No.
Name
Unit
Lower Limit
Upper
Limit
Factory
Setting