Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-121

5.8.3

Using More Than One Servodrive

The following diagram is an example of the wiring when more than one servodrive
is used.

Note: Wire the system to comply to National Electrical Code.

Connect the alarm output (ALM) terminals for the three servo amplifiers in series to
enable alarm detection relay 1RY to operate. The output transistor is turned OFF
when the ALM output signal enters an alarm state.
Multiple servos can share a single MCCB or noise filter. Always select an MCCB or
noise filter that has enough capacity for the total power capacity (load conditions) of

SGDH

Servo
amplifier

L1

L2

L3

L1C

L2C

CN1

31 ALM+

32 ALM-

M

SGDH

Servo
amplifier

L1

L2

L3

L1C

L2C

CN1

31 ALM+

32 ALM-

M

Fuse

SGDH

Servo
amplifier

L1

L2

L3

L1C

L2C

CN1

31 ALM+

32 ALM-

M

+24V 1RY

1MC

1MC

1MC

1RY

Power

Power

Supply

OFF

Supply

ON

Fuse

Fuse

SUP

Noise filter

MCCB

Power supply

R S T

Fuse

0V