Sigma II User’s Manual

Chapter 6: Servo Adjustment

6 - 14

6.2.4

Setting Speed Bias

The settling time for positioning can be reduced by assigning bias to the speed
reference block in the servo amplifier. To assign bias, use the following constants.

Set the parameters to shorten the time required for positioning according to the
application.
The bias increment width (Pn108) is expressed as an error pulse width that
determines the time in which bias input (Pn107) takes effect. The bias input is ON if
the error pulse width exceeds the value set in Pn108.

Parameter

Signal

Setting

(rpm)

Application

Pn107

Bias

Setting Range: 0 to 450

Default Setting: 0

Position Control

Pn108

Bias Addition Width

Setting Range: 0 to 250

Default Setting: 7

Position Control

Error pulse

Internal speed reference

Pn107

Bias increment width

Pn108