1 basic operation, 1 connecting the digital operator, 1 basic operation - 2 – Yaskawa Sigma II Series Servo System User Manual

Page 276: 1 connecting the digital operator - 2, 1 basic operation -2, Connecting the digital operator -2, Servo amplifier. digital operator to the

Advertising
background image

Sigma II User’s Manual

Chapter 7: Using the Digital Operator

7 - 2

7.1 Basic Operation

This section provides information on the basic operation of the digital operator for setting
operating conditions.

7.1.1

Connecting the Digital Operator

There are two types of digital operators. One is a built-in operator incorporating a
panel indicator and switches located on the front panel of the servo amplifier. This
type of digital operator is also called a panel operator. The other one is a hand-held
operator (i.e., the JUSP-OP02A-1 digital operator), which can be connected to the
servo amplifier through connector CN3 of the servo amplifier.
There is no need to turn OFF the servo amplifier to connect this hand-held operator
to the servo amplifier. Refer to the following illustrations to connect the hand-held
digital operator to the servo amplifier.

Note: If the hand-held digital operator is connected to the servo amplifier, the built-in panel operator does

not display anything.

YASKAWA

200V

MODE/SET

DATA/

SERVOPACK

ALARM

RESET

DIGITAL

OPERATOR

JUSP-OP02A-1

DSPL

SET

DATA

ENTER

JOG

SVON

YASKAWA

Hand-held Digital Operator

JUSP-OP02A-1

Built-in Panel Operator

CN3

Servo Amplifier

A single-purpose cable
(JZSP-CMS00-1) is

used to connect the

SGDH-

SERVOPACK

servo amplifier.

digital operator to the