1 names and descriptions of main circuit terminal – Yaskawa Sigma II Series Servo System User Manual

Page 51

Advertising
background image

Sigma II User’s Manual

Chapter 3: Wiring

3 - 13

3.3.1

Names and Descriptions of Main Circuit Terminal

The following table gives the names and a description of main circuit terminals.

Main Circuit Names and Description

Terminal

Symbol

Name

Description

L1, L2 or

L1, L2,

L3

Main circuit AC

input terminal

30W to 200W

Single-phase 100 to 115V

(+10%, -15%), 50/60Hz

30W to 400W

Single-phase 200 to 230V

(+10%, -15%), 50/60Hz

500W to 15kW

200V

Three-phase 200 to 230V

(+10%, -15%), 50/60Hz

500W to 55kW

400V

Three-phase 380 to 480V

(+10%, -15%), 50/60Hz

U, V, W

Servomotor

connection terminal

Connects to the Servomotor.

L1C, L2C

Control power input

terminal

30W to 200W

Single-phase 100 to 115V (+10%, -15%), 50/60Hz

30W to 15kW

Single-phase 200 to 230V (+10%, -15%), 50/60Hz

24V, 0V

500W to 55kW

24V

DC

(±15%) 400V units only

Ground terminal

Connects to the power supply ground terminals and motor ground terminal.

B1, B2

or

B1, B2,

B3

External

regenerative

resistor terminal

30W to 400W

Normally not connected.

Connect an external regenerative resistor (provided by

the user) between B1 and B2 if the regenerative capac-

ity is insufficient.

Note: No B3 terminal.

500W to 5.0kW

Normally short B2 and B3 (for an internal regenerative

resistor).

Remove the wire between B2 and B3 and connect an

external regenerative resistor (provided by customer)

between B1 and B2 if the capacity of the internal

regenerative resistor is insufficient.

B1, B2

6.0kW-55.0kW

Connect an external regenerative resistor (provided by

the user) between terminals B1 and B2. See 5.6

Selecting a Regenerative Resistor for details.

⊕1, ⊕2

DC reactor terminal

connection for

power supply

harmonic wave

countermeasure

Normally short

⊕1 and ⊕2.

If a countermeasure against power supply harmonic waves is needed, connect

a DC reactor between

⊕1 and ⊕2.

The amplifier is delivered from the factory with these terminals shorted. See

5.8.6 Reactor for Harmonic Suppression for details.

Main circuit

Negative terminal

Normally not connected.

Main circuit Positive

terminal

Normally not connected.