Torque control parameter, Internal speed limit function – Yaskawa Sigma II Series Servo System User Manual

Page 128

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 42

Torque Control Parameter

The following parameter is used for torque control. Set the parameter according to
requirements of the servo system that is used.

This parameter sets the voltage range for torque reference input T-REF (CN1-9)
depending on the output range of the host controller or external circuit.
The default setting is 30, so the rated torque output is equal to 3V (30 × 0.1).

Internal Speed Limit Function

This parameter sets a motor speed limit when torque control is selected. It is used to
prevent excessive equipment speed during torque control.
Since the speed limit detection signal /VLT functions the same in torque control as
the /CLT signal, see 5.1.3 Limiting Torque, where the /CLT signal is described

Parameter

Signal

Setting

(0.1V x rated torque)

Control Mode

Pn400

Torque Reference Input Gain

Setting Range: 10 to 100

Default Setting: 30

Speed/Torque Control

Pn002.1 Setting

Description

0

Uses speed limit set by Pn407 (internal speed limit function).

1

Uses V-REF (Cn1-5 and -6) as external speed limit input and sets speed

limit by voltage, which are input to V-REF and Pn300 (external speed limit

function).

Parameter

Signal

Setting

(rpm)

Control Mode

Pn407

Speed Limit during Torque Control

Setting Range: 0 to 10000

Default Setting: 10000

Speed/Torque Control

Reference

voltage (V)

Reference torque

This reference voltage is set.

Rated torque

Torque
control
range

Torque

Motor speed

Speed limit

Torque Control Range

Advertising