2 wiring for noise control, 2 wiring for noise control - 117, Wiring for noise control -117 – Yaskawa Sigma II Series Servo System User Manual

Page 203: 2 wiring for noise control wiring example, Correct grounding grounding the motor frame, Preferably a braided flat copper wire

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-117

5.8.2

Wiring for Noise Control

Wiring Example

This servo amplifier uses high-speed switching elements in the main circuit. It may
receive “switching noise” from these high-speed switching elements if wiring or
grounding around the servo amplifier is not appropriate. To prevent this, always
wire and ground the servo amplifier correctly.
This servo amplifier has a built-in microprocessor (CPU). To protect it from

external noise install a noise filter in the appropriate place.
The following is an example of wiring for noise control.

Notes: 1. When using a noise filter, follow the precautions in Using Noise Filters on the following page.

2. For ground wires connecting to the casing, use a wire with a thickness of at least 0.005in

2

(3.5mm

2

), preferably a braided flat copper wire.

Correct Grounding

Grounding the Motor Frame

Always connect servomotor frame terminal FG to the servo amplifier ground

terminal . Also be sure to ground the ground terminal .
If the servomotor is grounded via the machine, switching noise current will flow
from the servo amplifier power unit through motor stray capacitance. The

grounding of the motor frame is required to prevent the adverse effects of switching
noise.

M

(FG)

U

W

V

L2

L1

L3

L2C

L1C

CN2

CN1

Servomotor

P

P

P 1LF*

AVR

(Ground)

(Casing)

(Casing)

(Casing)

(Casing)

2LF

(Casing)

AC200V

PG

Noise filter***

Servo amplifier

P: Indicates twisted pair wires

•Operation relay

sequence

•Signal generation

circuit (provided

by user)

0.003in.

2

(2mm

2

) minimum

2)

0.003in.

2

0.005in

2

(3.5mm

2

)minimum

(2mm

2

)

minimum

0.005in

2

(3.5mm

2

)

minimum

Wires of 0.005in

2

(3.5mm

2

)minimum

0.005in.

2

(3.5mm

2

)

minimum

Advertising