Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-65

Setting Motor Speed

Use the following parameter to set the motor speed level at which zero clamp is

performed

If zero clamp speed control is selected, set the motor speed at which zero clamp is to
be performed. The maximum speed will be used if the value of Pn501 is set higher
than the maximum speed of the servomotor.

Zero Clamp Conditions

Zero clamp is performed when all the following conditions are satisfied:

Zero clamp speed control is selected (parameter Pn000.1 is set to A).

/P-CON (/ZCLAMP)(CN1-41) is ON (0V).

Speed reference drops below the setting level of Pn501.

Note: When the /ZCLAMP signal is allocated, the zero clamp operation will be used even for speed

control (Pn000.1 = 0).

Parameter

Signal

Setting

(rpm)

Description

Pn501

Zero Clamp Level

Setting Range: 0 to 10000

Default Setting: 10

Speed Control

V-REF speed reference

Speed

Open (OFF)

Closed

(ON)

Time

Preset value for zero clamping

/P-CON (/ZCLAMP) input

Zero clamp is performed