Single-phase power supply connection example – Yaskawa Sigma II Series Servo System User Manual
Page 211

Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-125
*1
This is the net value at the rated load.
When using a 400V class power supply, turn the power supply ON and OFF at the
primary side of the voltage conversion transformer.
Note: Transformer inductance will cause a surge voltage if the power is turned ON and OFF at the
secondary, damaging the servo amplifier.
Single-phase Power Supply Connection Example
Three-phase
200V
SGDH-05AE
1.4
SGDH-08AE
1.9
SGDH-10AE
2.3
SGDH-15AE
3.2
SGDH-20AE
4.3
SGDH-30AE
5.9
SGDH-50AE
7.5
SGDH-60AE
12.5
SGDH-75AE
15.5
SGDH-1AAE
22.7
SGDH-1EAE
30.9
Voltage
Servo Amplifier
Model
Voltage capacity per
Servo Amplifier
*1
kVA
U
V
W
1MC
1MC
1MC
Electromagnetic contactor for
power supply ON/OFF
Transformer for
voltage conversion
L1
L2
SGDH Servo amplifier
200V
AC
or 100V