Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-61

Position Control (Pulse Train Reference)

↔ Torque Control

(Analog Reference)

This mode switches between position and torque control through the /P-CON

(/C-SEL) signal.

Torque Control (Analog Reference)

↔ Speed Control (Analog

Reference)

This mode switches between torque and speed control through the /P-CON (/C-SEL)
signal. See 5.2.7 Using Torque Control.

Speed Control (Analog Reference)

↔ Zero Clamp

This speed control mode is used to set the zero clamp function when the servo

amplifier is stopped. Zero clamp operates when the /P-CON (/ZCLAMP) signal is
ON (low level). See 5.4.3 Using the Zero Clamp Function.

Position Control (Pulse Train Reference)

↔ Position Control

(Inhibit)

This mode controls positioning by inhibiting reference pulse input through the

/P-CON (/INHIBIT) signal. See 5.2.11 Reference Pulse Inhibit Function (/
INHIBIT)