Yaskawa Sigma II Series Servo System User Manual

Page 115

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 29

number of encoder signal pulses (A and B phase) output from the servo amplifier.

3. Determine the reference unit used.

A reference unit is the minimum position data unit used to move a load.

(Minimum unit of reference from the host controller).

Examples (in mm):

Reference unit can be 0.1in or 0.01in or 0.01mm or 0.001mm, etc.

A reference unit of one pulse moves the load by one reference unit.

When the reference unit is 1µm

If a reference of 50000 units is input, the load moves 50mm (1.97in)

(50000

× 0.001mm = 50mm).

4. Determine the load travel distance per load shaft revolution in reference units.

When the ball screw pitch is 0.20in (5mm) and the reference unit is
0.00004in (0.001mm),

Ball Screw

Disc Table

Belt and Pulley

Reference unit: 0.001mm

Determine the reference unit according to

equipment specifications and positioning accuracy.

To move a table in 0.001mm units

Travel distance per load shaft revolution = Travel distance per load shaft revolution

Reference Unit

0.20

0.00004

---------------------

5000

=

(reference units)

Load shaft

P

1 revolution =

P
reference unit

P: Pitch

L d h ft

Load shaft

1 revolution =

360°

reference unit

1 revolution =

πD

reference unit

D: Pulley

πΔ

Load shaft

Advertising