Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5 - 29

number of encoder signal pulses (A and B phase) output from the servo amplifier.

3. Determine the reference unit used.

A reference unit is the minimum position data unit used to move a load.

(Minimum unit of reference from the host controller).

Examples (in mm):

•

Reference unit can be 0.1in or 0.01in or 0.01mm or 0.001mm, etc.

A reference unit of one pulse moves the load by one reference unit.

•

When the reference unit is 1µm

If a reference of 50000 units is input, the load moves 50mm (1.97in)

(50000

× 0.001mm = 50mm).

4. Determine the load travel distance per load shaft revolution in reference units.

•

When the ball screw pitch is 0.20in (5mm) and the reference unit is
0.00004in (0.001mm),

Ball Screw

Disc Table

Belt and Pulley

Reference unit: 0.001mm

Determine the reference unit according to

equipment specifications and positioning accuracy.

To move a table in 0.001mm units

Travel distance per load shaft revolution = Travel distance per load shaft revolution

Reference Unit

0.20

0.00004

---------------------

5000

=

(reference units)

Load shaft

P

1 revolution =

P
reference unit

P: Pitch

L d h ft

Load shaft

1 revolution =

360°

reference unit

1 revolution =

πD

reference unit

D: Pulley

πΔ

Load shaft