Sigma II User’s Manual

Chapter 6: Servo Adjustment

6 - 26

Setting Parameters for Online Auto-Tuning

The following flowchart shows the procedure for setting the parameters for online
auto-tuning.

Start

Operate with factory

settings of parameters

Set to always perform tuning.

(Set Pn110.0 to 1)

Adjust the rigidity setting

(Set in Fn001)

Set so that online autotuning

is not performed.

(Set Pn110.0 to 2)

Load

inertia changes?

Operation

OK?

Adjust the friction

compensation.

Set in Pn110.2.

End

Make servo gain

adjustments manually *

No

Yes

No

No

No

No

Save the results of autotuning

to parameters. From the next

time, execute autotuning using

the calculated value as the

initial value.

Set in Fn007

Operation

OK?

Operation

OK?

Operation

OK?

Yes

Yes

Yes

.

Yes

*Before making manual servo gain adjustments, Refer to 6.4.3
Making Manual Adjustments

or 6.2 High-Speed Positioning.