5 improved functions, 1 moment of inertia ratio setting range, 2 adaptation to single-turn data absolute encoder – Yaskawa Sigma II Series Servo System User Manual

Page 226: Higher.) -140, Moment of inertia ratio setting range -140

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-140

5 Improved Functions

5.11 Improved Functions (Applicable only to SGDH amplifiers of version

#33

or higher.)

5.11.1 Moment of Inertia Ratio Setting Range

A load with moment of inertia ratio (Pn103) more than the existing maximum value
10,000% may be connected to a direct-drive motor. Accordingly, the upper limit of
Pn103 is increased to 20,000%. (100% = 1:1)

5.11.2 Adaptation to Single-turn Data Absolute Encoder

A single-turn data absolute encoder is mounted to SGMCS servomotor as standard.
The machine configuration with a SGMCS servomotor does not require harmonic
gear, etc. so that the servomotor can be connected directly to a load. Therefore, for
its absolute value detecting system, the load-end absolute value can be obtained by
measuring only the angle of motor shaft. 
In this case, the encoder multi-turn data is not required and no backup battery is
required.
(With a single-turn data absolute encoder, the multi-turn data is always set to"0")

Confirm the single-turn absolute encoder model in Motor Models Display (Fn011)
on the digital operator or panel operator:

FN011-E. □□■■ (Encoder Model/Encoder Resolution Display)

□□:

Encoder model

00: Incremental encoder

01: Multiturn data absolute encoder

02: Single-turn data absolute encoder

■■:

Encoder Resolution

13: 13 bits

16: 16 bits

17: 17 bits

20: 20 bits

Single-turn data absolute encoder

model

UTSB □ -B □□□□

Advertising