Yaskawa Sigma II Series Servo System User Manual

Page 429

Advertising
background image

Sigma II User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9 - 41

*1

These alarms are not reset by the alarm reset signal (/ALM-RST). Eliminate the cause of

the alarm and then turn OFF the power supply to reset the alarms.

2)

This alarm display appears only within the range of 30 to 1000W.

Notes:

OFF: Output transistor is OFF.
ON:

Output transistor is ON.

Alarm

Display

Alarm Code Output

ALM

Output

Alarm Name

Description

ALO1

ALO2

ALO3

A.81

OFF

OFF

OFF

OFF

Absolute Encoder
Backup Error

*

All the power supplies for the abso-

lute encoder have failed and position

data was cleared.

A.82

Encoder Checksum
Error

*

The checksum results of encoder

memory is abnormal.

A.83

Absolute Encoder

Battery Error

Battery voltage for the absolute

encoder has dropped.

A.84

Absolute Encoder Data
Error

*

Received absolute data is abnormal.

A.85

Absolute Encoder

Overspeed

The encoder was rotating at high

speed when the power was turned

ON.

A.86

Encoder Overheated

The internal temperature of encoder

is too high.

A.b1

Reference Speed Input

Read Error

The A/D converter for reference

speed input is faulty.

A.b2

Reference Torque Input

Read Error

The A/D converter for reference

torque input is faulty.

A.bF

System Alarm

*

A system error occurred in the servo

amplifier.

A.C1

ON

OFF

ON

OFF

Servo Overrun

Detected

The servomotor ran out of control.

A.C8

Absolute Encoder Clear

Error and

Multi-Turn Limit

Setting Error

*

The multi-turn for the absolute

encoder was not properly cleared or

set.

A.C9

Encoder

Communications
Error

*1

Communications between servo

amplifier and encoder is not possible.

A.CA

Encoder Parameter
Error

*1

Encoder parameters are faulty.

A.Cb

Encoder Echoback
Error

*1

Contents of communications with

encoder is incorrect.

A.CC

ON

OFF

ON

OFF

Multi-Turn Limit

Disagreement

Different multi-turn limits have been

set in the encoder and servo

amplifier.

A.d0

ON

ON

OFF

OFF

Position Error Pulse

Overflow

Position error pulse exceeded

parameter (Pn505).

A.E7

OFF

ON

ON

OFF

Option Unit Detection

Error

Option unit detection fails.

A.F1

OFF

ON

OFF

OFF

Power Line Open

Phase

One phase is not connected in the

main power supply

CPF00

Not Specified

Digital Operator

Transmission Error

Digital operator (JUSP-OP02A-2)

fails to communicate with servo

amplifier (e.g., CPU error).

CPF01

A.--

OFF

OFF

OFF

ON

Not an error

Normal operation status

Advertising