Safety Precautions

The following precautions are for checking products upon delivery, installation, wiring,
operation, maintenance and inspections.

Checking Products upon Delivery

Installation

Wiring

Always use the servomotor and servo amplifier in one of the specified combinations.

Not doing so may cause fire or malfunction.

Never use the products in an environment subject to water, corrosive gases, inflammable gases, or

combustibles.

Doing so may result in electric shock or fire.

Connect the ground terminal to a class 3 ground (100

Ω or less).

Improper grounding may result in electric shock or fire.

• Required for 7.5kW amplifiers:

Use of Yaskawa kit Number JZSP-CKT75 for wiring the power input and output terminals, or equivalent
UL listed closed-loop ring terminals designed to accept 4 AWG wires.

• Required for 200V, 11kW and 15kW amplifiers:

Use of Yaskawa kit number JZSP-CKT75 for wiring the power input and output terminals of the SGDH-
1AAE, and JZSP-CKT1E for the SGDH-1EAE, or equivalent UL listed closed-loop ring terminal to accept 4
AWG and 2 AWG wires respectively.

• Required for 400V, 6.0kW and 7.5kW amplifiers:

Use of Yaskawa kit Number JZSP-CKT75DE for wiring the power input and output terminals, or

equivalent UL listed closed-loop ring terminals designed to accept 8 AWG wires.

• Required for 400V, 11kW amplifiers:

Use of Yaskawa kit Number JZSP-CKT1ADE for wiring the power input and output terminals, or

equivalent UL listed closed-loop ring terminals designed to accept 8 AWG wires.

• Required for 400V, 15kW amplifiers:

Use of Yaskawa kit Number JZSP-CKT1EDE for wiring the power input and output terminals, or

equivalent UL listed closed-loop ring terminals designed to accept 6 AWG wires.

CAUTION

CAUTION

WARNING