B.6 Monitor Modes

The following list shows monitor modes available

Parameter

Content of Display

Unit

Remarks

Un000

Actual motor speed

rpm

—

Un001

Input speed reference

rpm

—

Un002

Internal torque reference

%

Value for rated torque

Un003

Rotation angle 1

pulse

Number of pulses from the origin

Un004

Rotation angle 2

degree

Angle from the origin (electrical angle)

Un005

Input signal monitor

—

—

Un006

Output signal monitor

—

—

Un007

Input reference pulse speed

rpm

—

Un008

Error counter value

reference units

Amount of position error

Un009

Accumulated load rate

%

Value for the rated torque

Displays in 10s cycle.

Un010

Allowable maximum motor speed/

dividing ratio

100 mm/s or

Pulse/scale

pitch

(

Pn280)

Displays in decimal codes.

Un011

Hall sensor signals

–

–

Un00A

Regenerative load rate

%

Value for the processable regenerative

power

Displays in 10s cycle.

Un00B

Power consumed by DB resistance

%

Value for the processable power when

dynamic brake is applied

Displays in 10s cycle.

Un00C

Input reference pulse counter

—

Displayed in hexadecimal.

Un00D

Feedback pulse counter

—

Displayed in hexadecimal.

Un100~

UN104

Reserved

—

—