B.6 monitor modes, The following list shows monitor modes available – Yaskawa Sigma II Series Servo System User Manual

Page 459

Advertising
background image

Sigma II User’s Manual

Appendix B: List of Parameters

B - 19

B.6 Monitor Modes

The following list shows monitor modes available

Parameter

Content of Display

Unit

Remarks

Un000

Actual motor speed

rpm

Un001

Input speed reference

rpm

Un002

Internal torque reference

%

Value for rated torque

Un003

Rotation angle 1

pulse

Number of pulses from the origin

Un004

Rotation angle 2

degree

Angle from the origin (electrical angle)

Un005

Input signal monitor

Un006

Output signal monitor

Un007

Input reference pulse speed

rpm

Un008

Error counter value

reference units

Amount of position error

Un009

Accumulated load rate

%

Value for the rated torque

Displays in 10s cycle.

Un010

Allowable maximum motor speed/

dividing ratio

100 mm/s or

Pulse/scale

pitch

Pn280)

Displays in decimal codes.

Un011

Hall sensor signals

Un00A

Regenerative load rate

%

Value for the processable regenerative

power

Displays in 10s cycle.

Un00B

Power consumed by DB resistance

%

Value for the processable power when

dynamic brake is applied

Displays in 10s cycle.

Un00C

Input reference pulse counter

Displayed in hexadecimal.

Un00D

Feedback pulse counter

Displayed in hexadecimal.

Un100~

UN104

Reserved

Advertising