Sigma II User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9 - 43

9.2.5

Warning Displays

The correlation between warning displays and warning code outputs is shown in the
following table.

Warning Displays and Outputs

Warnings (Additional Warning Display) (Applicable only to SGDH
amplifiers with version # 33

or higher)

Warning

Display

Warning Code Outputs

Warning

Name

Meaning of Warning

ALO1

ALO2

ALO3

A.91

ON

OFF

OFF

Overload

This warning occurs before either of

the overload alarms (A.71 or A.72)

occurs. If the warning is ignored and

operation continues, an overload

alarm may result.

A.92

OFF

ON

OFF

Regenerative

Overload

This warning occurs before the

regenerative overload alarm (A.32)

occurs. If the warning is ignored and

operation continues, a regenerative

overload alarm may result.

Warning

Display

Warning Code Output

Warning Name

Cause

Corrective

Actions

ALO1

ALO2

ALO3

A.90

×

×

×

Excessive

position error

warning

The position errors exceed the

setting in Pn51E.

Reduce the position

errors to the value

of Pn51E or less to

restore

automatically.

Advertising