Procedure for saving results of online auto-tuning, Using the hand-held digital operator, Using the built-in panel operator – Yaskawa Sigma II Series Servo System User Manual

Page 262

Advertising
background image

Sigma II User’s Manual

Chapter 6: Servo Adjustment

6 - 30

Procedure for Saving Results of Online Auto-Tuning

The procedure for saving the results of online auto-tuning is as follows:

Using the Hand-held Digital Operator

1.

Press the MODE/SET key to select Fn007 in the auxiliary function mode.

2.

Press the DATA/ENTER key. If the inertia ratio is 200%, for example, the fol-
lowing data will be displayed.

3.

Press the MODE/SET key. The following display will flash for 1 second and
then the inertia ratio will be saved.

4.

Press the DATA/ENTER key to return to the auxiliary function mode.

This completes the procedure for saving the results of online auto-tuning. When the
servo amplifier is turned ON again, the inertia ratio set in Pn103 will be used as the
default value.

Using the Built-in Panel Operator

1.

Press the MODE/SET key and select Fn007 in the auxiliary function mode.

2.

Press the DATA/SHIFT key for a minimum of 1 second. If the inertia ratio is
200%, for example, the following data will be displayed.

3.

Press the MODE/SET key. The following display will flash for 1 second and
then the inertia ratio will be saved.

4.

Press the DATA/SHIFT key for a minimum of 1 second to return to the auxiliary
function mode.

Flashes for

1 s.

Flashes for

1 s.

Advertising