A.71, A.72

A.71: Overload: High Load
A.72: Overload: Low Load.

The alarm output, status, and remedy for A.71 are the same as for A.72.

Display and Outputs

Note:

OFF:

Output transistor is OFF (alarm state).

ON:

Output transistor is ON.

Status and Remedy for Alarm

Alarm Outputs

Alarm Code Output

ALM Output

ALO1

ALO2

ALO3

ON

ON

ON

OFF

Cause of the Problem

Solution

A

Incorrect or disconnected servo-

motor wiring.

Check wiring and connectors at

the servomotor.

B

Load greatly exceeds rated

torque.

Reduce load torque and inertia.

Otherwise, replace with a larger

capacity servomotor.

C

Defective circuit board (1PWB).

Replace servo amplifier.

When Servo ON (S-ON)

signal is turned ON.

When speed reference

is entered.

At power ON.

C

B

B

A

No servomotor

rotation.

During servomotor

operation.