Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-81

The following parameter is used to output warning details with an alarm code.

The following warning codes are output in 3 bits.

Parameter

Signal

Setting

Description

Pn001.3

Warning Code Output Selection

Default Setting: 0

Speed/Torque Control,

Position Control

Pn001.3

Setting

Result

0

Outputs alarm codes alone for alarm codes

ALO1, ALO2 and ALO3.

1

Outputs both alarm and warning codes for

alarm codes ALO1, ALO2 and ALO3 and

outputs an alarm code when an alarm occurs.

Warning

Indication

Warning Code Output

Warning Description

ALO1

ALO2

ALO3

A.91

ON signal

(low level)

OFF signal

(high level)

OFF signal

(high level)

Overload

A.92

OFF signal

(high level)

ON signal

(low level)

OFF signal

(high level)

Regenerative overload

/WARN

Warning output

signal

Pn50F.3

1

2
3

CN1-25, 26 (SO1)
CN1-27, 28 (SO2)
CN1-29, 30 (SO3)

Output terminals

Advertising