A. b3

×

×

×

×

Current

detection error

For 1kW or smaller

models. Amplifier

stays in BB for 500ms

after servo ON signal

input and brake

release with the servo

in a ready state.

resettable

Check the

wiring in motor

power line.

Replace the

servo

amplifier.

A.F5

×

×

×

Motor

disconnection

alarm

The detected torque

is 10% or less, but the

commanded torque

reference is 90% or

more for 10ms. This

alarm is not activated

in cases of BB due to

hardware issues. In

those cases, an A.F6

or A.b3 is generated

instead.

resettable

Check the

wiring in motor

power line.

Replace the

servo

amplifier.

Warning List

Warning

Warning Code Output

Warning

Name

Warning Occurring Cause

Solution

ALO1

ALO2

ALO3

A.90

×

×

×

Excessive

Position Error

Warning

Position error exceeds

Pn51E.

If a position error

is within Pn51E, it

automatically

reset.