Limiting Torque

The SGDH servo amplifier limits torque as follows:

Level 1: Limits maximum output torque to protect the equipment or workpiece.

Level 2: Limits torque after the servomotor moves the equipment to a specified

position (internal torque limit).

Level 3: Always limits output torque rather than speed.

Level 4: Switches between speed and torque limit.

Application of levels 1 and 2 in the torque limit function are described below.

Setting Level 1: Internal Torque Limits

Maximum torque is limited to the values set in the following parameters.

Sets the maximum torque limits for forward and reverse rotation.

Used when torque must be limited due to equipment conditions.

The torque limit function always monitors torque and outputs the signals
below when the limit is reached.

The following signals are output by the torque limit function.

The torque limits are specified as a percentage of the rated torque.

Note: If torque limit is set higher than the maximum torque of the servomotor, the maximum torque of the

servomotor is the limit.

Parameter

Signal

Setting

(%)

Control Mode

Pn402

Forward Torque Limit

Range: 0 to 800

Default Setting: 800

Speed/Torque Control,

Position Control

Pn403

Reverse Torque Limit

Range: 0 to 800

Default Setting: 800

Speed/Torque Control,

Position Control

Signal

Description

/CLT

Generated when Pn50F.0 allocates an output terminal from SO1 to SO3.

Monitor Mode (Un006)

Output signal monitor