3 three-phase (400v) main circuit specifications, Three-phase (400v) main circuit specifications -6, Sigma ii user’s manual chapter 3: wiring 3 - 6 – Yaskawa Sigma II Series Servo System User Manual

Page 44

Advertising
background image

Sigma II User’s Manual

Chapter 3: Wiring

3 - 6

3.1.3

Three-Phase (400V) Main Circuit Specifications

Host
Controller

Connect the SGDH servo amplifier
to a Yaskawa host controller or to
one made by another company.

MEMOCON GL120, GL130

with a motion module.

Molded-Case Circuit

Breaker (MCCB)

Noise Filter

Magnetic Contactor

Brake Power Supply

Regenerative Resistor

Digital Operator

Personal Computer

Encoder

Cable

Encoder

Connector

JUSP-OPO2A-1

Allows the user to

set parameters or

operation references

and to display opera-

tion or alarm status.

Communication

and control is also

possible with a

personal computer.

Cable model: YS-12

Used to eliminate external

Protects the power

Used for a servomotor

Connect an external regenerative

line by shutting

OFF the circuit

when overcurrent

is detected.

HI Series

noise from the power line.

Turns the servo

ON and OFF.

Install a surge

suppressor on

the magnetic

contactor.

with a brake.

resistor to terminals B1 and B2

if the regenerative capacity

is insufficient.

and JZSP-CMS00-1

(cable)

Brake
power
supply

Magnetic

Magnetic
contactor

contactor

Power
supply
ground
line

Noise filter

Power supply
Three-phase 200V

AC

R S T

MCCB

Regenerative

resistor

(optional)

L1 L2 L3

24V 0V

B1 B2

Power supply for Brake

Supplied by 100V

ac

or 200V

ac

Supplied by 24V

DC

for

servomotor with 24V

DC

brake.

24V

DC

Power Supply

For 6kW or higher, an external

resistor is required.

Advertising