Pso serial data specifications – Yaskawa Sigma II Series Servo System User Manual

Page 193

Advertising
background image

Sigma II User’s Manual

Chapter 5: Parameter Settings and Functions

5-107

Detailed Signal Specifications

PAO Serial Data Specifications

The number of revolutions is output in five digits.

Note: 1. Data is “P+00000” (CR) or “P-00000” (CR) when the number of revolutions is zero.

2. The revolution range is “+32767” to “-32768.” When this range is exceeded, the data changes

from “+32767” to “-32768” or from “-32768” to “+32767”

PSO Serial Data Specifications

The number of revolutions and the absolute position within one revolution are
always output in five and seven digits, respectively. The data output cycle is

approximately 40ms.

Data Transfer Method

Start-stop Synchronization

(ASYNC)

Baud rate

9600bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

8 characters, as shown below.

Data Transfer Method

Start-stop Synchronization

(ASYNC)

Baud rate

9600bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

13 characters, as shown below.

0 0 0 0 0 1 0 1 0

Data

Start bit

Even parity

1

Stop bit

“P” “+” or “-” “0” to “9” “CR”