LLDP Commands

www

.dell.com | support.dell.com

lldp timers

Use the lldp timers command in Global Configuration mode to set the timing parameters for local
data transmission on ports enabled for LLDP. To return any or all parameters to factory default, use
the no form of this command.

Syntax

lldp timers [interval transmit-interval] [hold hold-multiplier] [reinit reinit-delay]

no lldp timers [interval] [hold] [reinit]

transmit-interval—The interval in seconds at which to transmit local data LLDPDUs. (Range:
1 - 32768 seconds)

hold-multiplier —Multiplier on the transmit interval used to set the TTL in local data
LLDPDUs. (Range: 2 - 10)

reinit-delay —The delay in seconds before re-initialization. (Range: 1 - 10 seconds)

Default Configuration

The default transmit interval is 30 seconds.

The default hold-multiplier is 4.

The default delay before re-initialization is 2 seconds.

Command Mode

Global Configuration mode

User Guidelines

This command has no user guidelines.

Examples

The following example displays how to configure LLDP to transmit local information every
1000 seconds.

console(config)#lldp timers interval 1000

The following example displays how to set the timing parameter at 1000 seconds with a hold
multiplier of 8 and a 5 second delay before re-initialization.

console(config)#lldp timers interval 1000 hold 8 reinit 5

lldp transmit

Use the lldp transmit command in Interface Configuration mode to enable the LLDP advertise
(transmit) capability. To disable local data transmission, use the no form of this command.