Switchport trunk allowed vlan – Dell PowerEdge M805 User Manual

Page 535

Advertising
background image

VLAN Commands

531

Default Configuration

This command has no default configuration.

Command Mode

Global Configuration mode

User Guidelines

This command has no user guidelines.

Example

The following example assigns the name "protected" to group 1.

console(config-if-1/g1)#switchport protected 1 name protected

switchport trunk allowed vlan

Use the switchport trunk allowed vlan command in Interface Configuration mode to add VLANs
to or remove VLANs from a trunk port.

Syntax

switchport trunk allowed vlan {add vlan-list|remove vlan-list}

add vlan-list—List of VLAN IDs to add. Separate non-consecutive VLAN IDs with a
comma and no spaces. Use a hyphen to designate a range of IDs.

remove vlan-list—List of VLAN IDs to remove. Separate non-consecutive VLAN IDs
with a comma and no spaces. Use a hyphen to designate a range of IDs.

Default Configuration

This command has no default configuration.

Command Mode

Interface Configuration (Ethernet, port-channel) mode

User Guidelines

This command has no user guidelines.

Example

The following example shows how to add VLANs 1, 2, and 5 to 8 to the allowed list.

console(config-if-1/g8)#switchport trunk allowed vlan add 1,2,5-8