Dell PowerEdge M805 User Manual

Page 448

Advertising
background image

440

SNMP Commands

www

.dell.com | support.dell.com

Syntax

snmp-server v3-host {ip-address | hostname} username {traps | informs} [noauth | auth |
priv] [timeout seconds] [retries retries] [udpport port] [filter filtername]

no snmp-server host ip-address

ip-address—Specifies the IP address of the host (targeted recipient).

hostname—Specifies the name of the host. (Range:1-158 characters.)

username—Specifies user name to use to generate the notification. (Range:1-25
characters.)

traps—Indicates that SNMP traps are sent to this host.

informs—Indicates that SNMPv2 informs are sent to this host.

noauth—Specifies sending of a packet without authentication.

auth—Specifies authentication of a packet without encrypting it

priv—Specifies authentication and encryption of a packet.

seconds—Number of seconds to wait for an acknowledgment before resending informs.
This is not allowed for hosts configured to send traps. The default is 15 seconds.
(Range:1-300 seconds.)

retries—Maximum number of times to resend an inform request. This is not allowed for
hosts configured to send traps. The default is 3 attempts. (Range:1-255 retries.)

port—UDP port of the host to use. The default is 162. (Range:1-65535.)

filtername—A string that is the name of the filter that define the filter for this host. If
unspecified, does not filter anything. (Range:1-30 characters.)

Default Configuration

Default configuration is 3 retries and 15 seconds timeout.

Command Mode

Global Configuration mode

User Guidelines

This command has no user guidelines.

Example

The following example identifies an SNMPv3 host.

console(config)# snmp-server v3-host 192.168.0.20

Advertising