Syntax

ip igmp query-max-response-time tenthsofseconds

no ip igmp query-max-response-time

tenthsofseconds—Maximum response time. (Range: 0-255 seconds)

Default Configuration

100 tenths of seconds is the default maximum response time value.

Command Mode

Interface Configuration (VLAN) mode

User Guidelines

This command has no user guidelines.

Example

The following example configures a maximum response time interval of one second for VLAN
15.

console(config)#interface vlan 15

console(config-if-vlan15)#ip igmp query-max-response-time 10

ip igmp robustness

Use the ip igmp robustness command in Interface Configuration mode to configure the robustness
that allows tuning of the interface, that is, tuning for the expected packet loss on a subnet. If a
subnet is expected to have significant loss, the robustness variable may be increased for the
interface.

Syntax

ip igmp robustnest robustness

no ip igmp robustnest

robustness—Robustness variable. (Range: 1-255)

Default Configuration

2 is the default robustness value.