Parameter Settings for Autotuning

The following parameters must be set before autotuning.

Table 4.3 Parameter Settings before Autotuning

Parameter

Number

Name

Display

Setting

Range

Factory

Setting

Data Displays during Autotuning

V/f

V/f with

PG

Open-

loop

Vector

1

Flux

Vector

Open-

loop

Vector

2

Display

T1-00

Motor 1/2
selection

*1

When switching to motor 2 is
selected, set the motor for
which autotuning is to be per-
formed. (This parameter is
ignored if motor 2 is not
selected.)
1: Motor 1
2: Motor 2

1 or 2

1

Yes

Yes

Yes

Yes

Yes

Select
Motor

T1-01

Autotun-
ing mode
selection

Set the autotuning mode.

0: Rotational autotuning
1: Stationary autotuning
2: Stationary autotuning for

line-to-line resistance only

0 to 2

2 (V/f)

0 (Vec-

tor)

*4

Yes

Yes

Yes

Yes

Yes

Tuning
Mode Sel

T1-02

Motor
output
power

Set the output power of the
motor in kilowatts.

*5 *7

0.00 to

650.00 kW

0.40 kW

*2

Yes

Yes

Yes

Yes

Yes

Mtr Rated
Power

T1-03

Motor
rated
voltage

Set the rated voltage of the
motor in volts.

*5 *6

0 to

255.0 V

(200-240 V

class)

0 to

510.0 V

(380-480 V

class)

200.0 V

(200-240

V class)
400.0 V

(380-480

V class)

-

-

Yes

Yes

Yes

Rated
Voltage

T1-04

Motor
rated
current

Set the rated current of the
motor in amps.

*5 *7

0.32 to

6.40 A

*3

1.90 A

*2

Yes

Yes

Yes

Yes

Yes

Rated
Current

T1-05

Motor
base fre-
quency

Set the base frequency of the
motor in hertz.

*3 *4 *5 *6

0 to

400.0 Hz

60.0Hz

-

-

Yes

Yes

Yes

Rated Fre-
quency

Advertising