Yaskawa G7 Drive User Manual

Page 38

Advertising
background image

Wiring Main Circuit Terminals

2-

7

* The wire thickness is set for copper wires at 75

°C

G7U2037

R/L1, S/L2, T/L3,

,

1 U/T1,

V/T2, W/T3, R1/L11, S1/L21, T1/L31

M10

155 to 198

(17.6 to 22.5)

N/A

3/0

(80)

Power cables,
e.g., 600 V
vinyl power
cables

3

M8

78 to 95

(8.8 to 10.8)

Application

Dependent

M10

155 to 198

(17.6 to 22.5)

1

(38)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

16

(1.25)

G7U2045

R/L1, S/L2, T/L3,

,

1, U/T1, V/T2,

W/T3, R1/L11, S1/L21, T1/L31

M10

155 to 198

(17.6 to 22.5)

1/0

× 2P

(50

× 2P)

3

M8

78 to 95

(8.8 to 10.8)

Application

Dependent

M10

155 to 198

(17.6 to 22.5)

1/0

(50)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

16

(1.25)

G7U2055

, 1

M12

276 to 345

(31.4 to 39.2)

3/0

× 2P

(80

× 2P)

R/L1, S/L2, T/L3, U/T1, V/T2, W/T3,
R1/L11, S1/L21, T1/L31

M10

155 to 198

(17.6 to 22.5)

3/0

× 2P

(80

× 2P)

3

M8

78 to 95

(8.8 to 10.8)

Application

Dependent

M12

155 to 198

(17.6 to 22.5)

2/0

(80)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

16

(1.25)

G7U2075

R/L1, S/L2, T/L3,

,

1

M12

276 to 345

(31.4 to 39.2)

250

× 2P

(150

× 2P)

U/T1, V/T2, W/T3, R1/L11, S1/L21,
T1/L31

M12

276 to 345

(31.4 to 39.2)

4/0

× 2P

(100

× 2P)

3

M8

78 to 95

(8.8 to 10.8)

Application

Dependent

M12

276 to 345

(31.4 to 39.2)

2/0

× 2P

(60

× 2P)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

16

(1.25)

G7U2090

R/L1, S/L2, T/L3,

,

1

M12

276 to 345

(31.4 to 39.2)

350

× 2P, or

1/0

× 4P

(200

× 2P, or

50

× 4P)

U/T1, V/T2, W/T3, R1/L11, S1/L21,
T1/L31

M12

276 to 345

(31.4 to 39.2)

300

× 2P, or

1/0

× 4P

(150

× 2P, or

50

× 4P)

3

M8

78 to 95

(8.8 to 10.8)

Application

Dependent

M12

276 to 345

(31.4 to 39.2)

300

× 2P

(150

× 2P)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

16

(1.25)

G7U2110

R/L1, S/L2, T/L3,

,

1

M12

276 to 345

(31.4 to 39.2)

350

× 2P, or

1/0

× 4P

(200

× 2P, or

50

× 4P)

U/T1, V/T2, W/T3, R1/L11, S1/L21, T1/
L31

M12

276 to 345

(31.4 to 39.2)

300

× 2P, or

1/0

× 4P

(150

× 2P, or

50

× 4P)

3

M8

78 to 95

(8.8 to 10.8)

N/A

Application

Dependent

M12

276 to 345

(31.4 to 39.2)

N/A

300

× 2P

(150

× 2P)

r/ 1, / 2

M4

11.4 to 12.3

(1.3 to 1.4)

N/A

16

(1.25)

Drive Model

CIMR-†

Terminal Symbol

Terminal

Screws

Clamping

Torque

lb•in(N•m)

Terminal

Block

Acceptable

Wire Range

AWG(mm

2

)

Recommended

Wire Size

AWG

(mm

2

)

Wire Type

Advertising