7

-14

OPE10

V/f Ptrn Set-

ting

V/f data setting error

Parameters E1-04, E1-06, E1-07, and E1-09 do not satisfy the following conditions:
• E1-04 (FMAX)

≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN)

• E3-02 (FMAX)

≥ E3-04 (FA) > E3-05 (FB) ≥ E3-07 (FMIN)

OPE11

Carr Freq/

On-Delay

Parameter setting error

One of the following parameter setting errors exists.
• C6-05 (Carrier Frequency Gain) > 6, the Carrier Frequency Lower Limit (C6-04)

> the Carrier Frequency Gain(C6-05)

• Upper/lower limit error in C6-03 to 05.
• C6-01 is 0 and C6-02 is 2 to E.
• C6-01 is 1 and C6-02 is 7 to E.

ERR

EEPROM

R/W Err

EEPROM write error

A verification error occurred when writing EEPROM.
• Try turning the power supply off and on again.
• Try setting the parameters again.

Table 7.3 Operation Error Displays and Incorrect Settings (Continued)