Run indicator, Stop indicator, Drive modes – Yaskawa G7 Drive User Manual

Page 78: Modes

Advertising
background image

Drive Mode Indicators

3-

5

‹

Run Indicator

The status of the “RUN” indicator is shown in Table 3.5 when the Drive is in either the “LOCAL” or “REMOTE” mode.

‹

Stop Indicator

The status of the “STOP” indicator is shown in Table 3.6 when the Drive is in either the “LOCAL” or “REMOTE” mode.

Modes

This section describes the Drive's modes and switching between modes.

‹

Drive Modes

The Drive's user parameters and monitoring functions are organized in groups called modes that make it easier to
read and set user parameters.The Drive is equipped with 5 modes.
The 5 modes and their primary functions are shown.

* Always perform autotuning with the motor before operating using vector control. Autotuning mode will not be displayed during operation or when an

error has occurred. The default setting of the Drive is for open-loop vector control 1 (A1-02 = 2).

Table 3.5 RUN Indicator

Indicator Status

Condition

On

Drive is running.

Blinking

Drive is decelerating to a stop.

Off

Drive is stopped.

Table 3.6 STOP Indicator

Indicator Status

Condition

On

Drive is decelerating to a stop or stopped.

Blinking

Drive is in a run condition but the frequency reference is less than the
minimum output frequency E1-09, or the Drive is running in “REMOTE” mode and the
“STOP” key on has been pressed.

Off

Drive is running.

Table 3.7 Modes

Mode

Primary function(s)

Drive mode

The Drive can be run in this mode.
Use this mode when monitoring values such as frequency references or output cur-
rent, displaying fault information, or displaying the fault history.

Quick programming mode

Use this mode to reference and set the minimum user parameters to operate the
Drive (e.g., the operating environment of the Drive and Digital Operator).

Advanced programming mode

Use this mode to reference and set all user parameters.

Verify mode

Use this mode to read/set user parameters that have been changed from their fac-
tory-set values.

Autotuning mode*

Use this mode when running a motor with unknown motor parameters in the vector
control mode. The motor parameters are calculated and set automatically.
This mode can also be used to measure only the motor line-to-line resistance.